Elaborately Design ST100 Series Deft VFD

Elaborately Design ST100 Series Deft VFD

1,Larger rated current design, larger overload current and shorter acceleration time; 2,The over-excitation function is automatically added during the deceleration process, and the deceleration time is shorter; 3,Powerful overmodulation capability, higher output voltage with the same input voltage; 4,Powerful overload suppression to ensure that the inverter does not stop due to overload faults at maximum output; 5,Support Modbus/CanLink bus communication, easy to realize industrial automation networking; 6,Support CANlink bus mode and support synchronous control.

Product Details

Elaborately Design ST100 Series Deft VFD

ModelHole to   Hole (mm)Overall   Dimensions (mm)Mounting Hole Diameter
     (mm)
Weight (kg)
ABHH1WD
Single-phase 220 V
SVD-PS0.4GB113172186/125164ø5.01.1
SVD-PS0.7GB
SVD-PS1.5GB
SVD-PS2.2GB
Three-phase 380 V
MD380T0.7GB113172186/125164ø5.01.1
MD380T1.5GB
MD380T2.2GB
MD380T3.7GB148236248/160183ø5.02.5
MD380T5.5GB
MD380T7.5GB
MD380T11GB190305322/208192ø66.5
MD380T15GB
MD380T18.5G


New Design VFD


Specification
Standard functionsMaximum   frequency 0–500 Hz
Carrier frequency0.8–11   kHz  automatically adjusted according   to the load features.
Input frequency resolutionDigital   setting: 0.01 Hz, Analog setting: maximum frequency x 0.025%
Control mode•   Sensorless flux vector(SFVC)  • V/F
Overload capacity•   60s for 150%, 2s for 180%
Torque boost•   Automatic boost   • Customized boost   0.1%–30.0%
V/F curve•   Straight-line V/F curve  • Multi-point   V/F curve
Ramp mode•   Straight-line  • S-curve  • Four groups of acceleration/deceleration   time with the range of 0.0–6500.0s
DC braking•Braking   frequency: 0.00 Hz to maximum frequency • Braking time: 0.0–36.0s
JOG controlJOG   frequency range: 0.00–50.00 Hz acceleration/deceleration time: 0.0–6500.0s
Onboard multiple preset speedsUp   to 8 speeds via the simple PLC function    or combination of DI terminal states.
Built-in Programmable PIDFor   process-controlled closed loop control system
Auto voltage regulation (AVR)Maintain   output voltage automatically against the input mains voltage fluctuation.
Stall controlAutomatic   current and voltage limitation to avoid frequent tripping due to   overvoltage/overcurrent. protection
Torque limit and controlAutomatic   torque limitation avoid frequent over current protection  tripping
Power dip ride throughManage   speed of motor to ride through short period power dip/interruption
Rapid current limitIt   helps to avoid frequent overcurrent faults of the AC drive.
Timing controlTime   range: 0.0–6500.0 minutes
Built-in CommunicationModbus-RTU.
Running controlRunning   command source•   Operation panel • Control terminals • Serial communication port
Frequency sourceup   to 5 frequency sources,: digital setting, analog input, pulse  and    communication port setting.
Auxiliary frequency source5   auxiliary frequency sources. capable of    auxiliary frequency tuning and frequency synthesis.
Input terminal4   digital input (DI) terminals, one supports up to 20 kHz high-speed pulse   input , 1 analog input (AI) terminals,    supports 0–10 V / or 4–20 mA    input
Output terminal1 relay output terminal, 1   analog output (AO) terminal that supports 0–20 mA, current output or 0–10 V   voltage output •
Display and  operation   panelDisplay5digit   LED numeric displays with LED indicator the status and parameters of the AC   drive system
Key locking and function selectionlock the keys partially or   completely and define the function range of some keys so as to prevent   malfunction.
Protection modeMotor   short-circuit detection at power-on, input/output phase loss protection,   overcurrent protection, overvoltage protection, under voltage protection,   overheat protection and overload protection
EnvironmentInstallation   locationIndoor, avoid direct sunlight,   dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
AltitudeLower   than 1000 m
operation temperature .-10°C to   +50°C  derating needed between 40~50°C
Humidity0~   97%RH, non condensing
VibrationLess than 5.9   m/s2 (0.6 g)
Storage temperature-20°C   to +60°C
IP levelIP20
Power distribution system TN/TT

Deft VFD

Elaborately Design VFD

Previous:No Information Next:No Information